Service Connectors

From PS3 Developer wiki
Jump to navigation Jump to search
PS3 Service Connector 1st Generation COK-002

JTAG/UART/SPI/Diagnostic I/O used in Sony repair centers if a PS3 couldn't be fixed by software.

Notes:

Service Connectors

Preproduction Generation

Used on Type of Connector
MPU-501 (CEB-2040) CN6504: Headerpins
CN6507: ZIF Connector

CN6504 (SC_JTAG)

MPU-501 CN6504 SC_JTAG
Pin Pogo-Pin Con. Name Connected to Function Group
1 NO ? ? ?
2 NO ? ? ?
3 NO ? ? ?
4 NO ? ? ?
5 NO ? ? ?
6 NO ? ? ?
7 NO ? ? ?
8 NO ? ? ?
9 NO ? ? ?
10 NO ? ? ?
11 NO ? ? ?
12 NO ? ? ?
13 NO ? ? ?
14 NO ? ? ?
15 NO ? ? ?
16 NO ? ? ?
17 NO ? ? ?
18 NO ? ? ?
19 NO ? ? ?
20 NO ? ? ?

CN6507 (STATUS)

Pin Pogo-Pin Con. Name Connected to Function Group
1 NO ? ? ?
2 NO ? ? ?
3 NO ? ? ?
4 NO ? ? ?
5 NO ? ? ?
6 NO ? ? ?
7 NO ? ? ?
8 NO ? ? ?
9 NO ? ? ?

CN6504 (SC_JTAG) (DECR)

TMU-520 CN6504 SC_JTAG
Pin Pogo-Pin Con. Name Connected to Function Group
1 NO GND DC-DC Regulator Ground line -
2 YES SC_RESET/RST Syscon System Reset Syscon JTAG
3 NO +3.3V_EVER DC-DC Regulator +3.3V line -
4 YES JRTCK Syscon Return Test Clock Syscon JTAG
5 YES JTCK Syscon Test Clock
6 YES JTMS Syscon Test Mode Select
7 YES JTDO Syscon Test Data Out
8 YES JTDI Syscon Test Data In
9 YES JNTRST Syscon Test Reset
10 YES-JL7500 VDDF / +3.3V_EVER DC-DC Regulator +3.3V line -

Diag/Backup (DECR)

Pin Pogo-Pin Con. Name Connected to Function Group
- ?? Backup Mode? SysCon Backup Mode? Syscon Modes
- ?? Diag Mode? SysCon Diagnose Mode?

SC_UART (DECR)

Pin Pogo-Pin Con. Name Connected to Function Standby Voltage Group
- (JL6839) +3.3V_EVER? DC-DC Regulator +3.3V line? 3.3 -
- (JL6838) Rx? Syscon Receive UART? 0 Syscon UART
- (JL6837) Tx? Syscon Transfer UART? 3.14
- (JL6836) GND? DC-DC Regulator Ground line 0 -

Pictures (Traces from DECR)

1st Generation

Used on Type of Connector
COOKIE-13 ZIF Connector
COK-001 (Prototype) Plain socket
COK-001 Plain socket
COK-002 Plain socket
COK-002W Plain socket

CN4009

First Generation Connector as seen on COK-002
First Generation Connector as seen on COK-001
First Generation Connector as seen on COOKIE-13
Pogo-pins to Testpoints on COK-001
Pin Pogo-Pin Con. Name Connected to Function Group
1 NO +5V_EVER DC-DC Regulator +5V line -
2 YES TRST Syscon Test Reset (nTRST) Syscon JTAG
3 YES TDI Syscon Test Data In
4 YES RTCK Syscon Return Test Clock
5 YES TCK Syscon Test Clock
6 YES TDO Syscon Test Data Out
7 YES TMS Syscon Test Mode Select
8 YES SC_RESET Syscon System Reset (nSRST)
9 NO GND DC-DC Regulator Ground line -
10 YES RxD Syscon Serial Receive Syscon UART
11 YES TxD Syscon Serial Transmit
12 NO GND DC-DC Regulator Ground line -
13 YES Diag Mode Syscon Diagnose Mode Syscon Modes
14 YES Backup Mode Syscon Backup Mode
15 NO +3.3V_EVER DC-DC Regulator +3.3V line -
16 YES NC - -
17 NO RMC Syscon Remote Control Syscon Modes
18 NO SB_TxD South Bridge Serial Transmit South Bridge UART
19 NO SB_RxD South Bridge Serial Receive
20 NO SW_4_A (W)LAN Power Switch LAN & WLAN
21 NO BE_TRG_OUT CELL BE Trigger Out Component Tests
22 NO RSX_TRG_OUT RSX Trigger Out
23 NO SB_TRG_OUT South Bridge Trigger Out
24 NO BE_CHKSTP_OUT CELL BE Checkstop Out
25 NO RSX_CHKSTP_OUT RSX Checkstop Out
26 NO SB_CHKSTP_OUT South Bridge Checkstop Out
27 NO +1.2V_MC_VDDIO DC-DC Regulator +1.2V line -
28 NO +1.5V_RSX_VDDIO DC-DC Regulator +1.5V line
29 NO GND DC-DC Regulator Ground line
30 NO +5V_EVER DC-DC Regulator +5V line

CELL_BE JTAG Testpads

CELL BE JTAG Testpads as seen on COK-001 and COK-002
Pin Pogo-Pin Con. Name Connected to Function Group
CL1103 YES TDO pin AW14 @ CELL BE Test Data Out CELL BE JTAG
CL1104 YES TDI pin AW13 @ CELL BE Test Data In
CL1105 YES TCK pin BA13 @ CELL BE Test Clock
CL1106 YES TMS pin AW12 @ CELL BE Test Mode Select
CL1107 YES /TRST pin AV14 @ CELL BE Test Reset (nTRST)

2nd Generation

Used on Type of Connector
SEM-001 Plain socket
DIA-001 Plain socket
DIA-002 Plain socket
DEB-001 Plain socket
Second Generation Connector as seen on DIA-001

CN4003

Pin Pogo-Pin Con. Name Connected to Function Group
10 YES SC_TXD SysCon Serial Transmit Syscon UART
9 YES SC_RXD SysCon Serial Receive
8 NO RMC SysCon Remote Control Syscon Modes
7 YES Diag Mode SysCon Diagnose Mode
6 YES Backup Mode SysCon Backup Mode
5 NO SB_SIO0_RXD_M South Bridge Serial Receive South Bridge UART
4 NO SB_SIO0_TXD_M South Bridge Serial Transmit
3 NO SW_4_B USB Power Switch USB
2 NO +5V_EVER DC-DC Regulator +5V line -
1 NO GND DC-DC Regulator Ground line

CN4004

Pin Pogo-Pin Con. Name Connected to Function Group
10 YES TRST SysCon Test Reset (nTRST) Syscon JTAG
9 YES TDI SysCon Test Data In
8 YES RTCK SysCon Return Test Clock
7 YES TCK SysCon Test Clock
6 YES TDO SysCon Test Data Out
5 YES TMS SysCon Test Mode Select
4 YES SC_RESET SysCon System Reset (nSRST)
3 NO +3.3V_EVER DC-DC Regulator +3.3V line -
2 NO GND DC-DC Regulator Ground line
1 NO GND DC-DC Regulator Ground line
Second Generation Connector as seen on SEM-001

CN1001 (CELL_BE_JTAG)

Pin Pogo-Pin Con. Name Connected to Function Group
12 NO GND DC-DC Regulator Ground line
11 NO +1.2V_MC2_VDDIO DC-DC Regulator +1.2V Line
10 NO GND DC-DC Regulator Ground line
9 NO BE_POWGOOD CELL BE Power Good
8 NO BE_RESET CELL BE Cell Reset
7 NO /BE_CHKSTP_OUT CELL BE Cell Checkstop Out
6 NO /BE_RESET_AND CELL BE Cell Reset?
5 NO BE_TDO CELL BE Test Data Out
4 NO BE_TMS CELL BE Test Mode Select
3 NO BE_TCK CELL BE Test Clock
2 NO BE_TRST CELL BE Test Reset (nTRST)
1 NO BE_TDI CELL BE Test Data In

3rd Generation

Used on Type of Connector
VERTIGO-002 Unknown Connector
VER-001 Plain socket
DYN-001 Plain socket
SURTEES-03 Unknown Connector
SUR-001 Plain socket
JTP-001 Plain socket
JSD-001 Plain socket
KTEN-04 Unknown Connector
KTE-001 Plain socket
MSX-K02 Unknown Connector
MSX-001 Plain socket
MPX-001 Plain socket
NPX-001 Plain socket
PPX-001 Plain socket
PQX-001 Plain socket

CN????

Pin Pogo-Pin Con. Name Connected to Function Group
14 NO ? ? ?
13 YES Backup Mode? SysCon Backup Mode Syscon Modes
12 YES Diag Mode? SysCon Diagnose Mode
11 YES SC_RxD SysCon Serial Receive Syscon UART
10 YES SC_TxD SysCon Serial Transmit
9 NO ? SysCon ?
8 NO ? SysCon ?
7 NO ? SysCon ?
6 NO ? ? ?
5 NO ? ? ?
4 NO ? ? ?
3 NO ? SysCon ?
2 NO GND DC-DC Regulator Ground Line -
1 NO +5V_EVER DC-DC Regulator +5V Line

http://pastie.org/private/h8osu80ksjr0xdta97zida#1-2,10-11