Talk:Syscon Firmware: Difference between revisions

From PS3 Developer wiki
Jump to navigation Jump to search
m (Created page with "[http://www.multiupload.com/F388R44T3X SYS_CON_FIRMWARE-PKGs.rar (51.92 KB)] SYS_CON_FIRMWARE_01000004.pkg (5376 bytes) Firmware 1.30 up to 1.80 (not 1.81 and higher) SYS_CON...")
 
mNo edit summary
Line 12: Line 12:
  SYS_CON_FIRMWARE_S1_00010002083E0832.pkg (5376 bytes) Firmware 3.00/3.01/3.10/3.15/3.20/3.21/3.30/3.40/3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65  
  SYS_CON_FIRMWARE_S1_00010002083E0832.pkg (5376 bytes) Firmware 3.00/3.01/3.10/3.15/3.20/3.21/3.30/3.40/3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65  
  SYS_CON_FIRMWARE_01050101.pkg (5376 bytes) Firmware 3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65
  SYS_CON_FIRMWARE_01050101.pkg (5376 bytes) Firmware 3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65
Updater log lines related to Syscon just after BD firmware, Multi-Card controller, BlueTooth firmware (in this case CEX 3.55) just before post processing and cleanup update status :
Update System controller firmware
read SC patch package (4864 bytes) elapsed = 3 msec
read SC patch package (4864 bytes) elapsed = 3 msec
read SC patch package (4864 bytes) elapsed = 3 msec
read SC patch package (4864 bytes) elapsed = 2 msec
read SC patch package (4864 bytes) elapsed = 2 msec
read SC patch package (4864 bytes) elapsed = 3 msec
read SC patch package (4864 bytes) elapsed = 2 msec
read SC patch package (4864 bytes) elapsed = 3 msec
Update System controller firmware done(0x8002f000)

Revision as of 01:14, 21 June 2011

SYS_CON_FIRMWARE-PKGs.rar (51.92 KB)

SYS_CON_FIRMWARE_01000004.pkg (5376 bytes) Firmware 1.30 up to 1.80 (not 1.81 and higher) 
SYS_CON_FIRMWARE_01000005.pkg (5376 bytes) Firmware 1.81 up to 3.30 (not 3.40 and higher) 
SYS_CON_FIRMWARE_01000006.pkg (5376 bytes) Firmware 3.40/3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65 
SYS_CON_FIRMWARE_01010302.pkg (5376 bytes) Firmware 1.81 up to 3.30 (not 3.40 and higher) 
SYS_CON_FIRMWARE_01010303.pkg (5376 bytes) Firmware 3.40/3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65
SYS_CON_FIRMWARE_01020302.pkg (5376 bytes) Firmware 3.40/3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65
SYS_CON_FIRMWARE_01030302.pkg (5376 bytes) Firmware 3.40/3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65
SYS_CON_FIRMWARE_01040402.pkg (5376 bytes) Firmware 3.40/3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65
SYS_CON_FIRMWARE_01050002.pkg (5376 bytes) Firmware 3.40/3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65 
SYS_CON_FIRMWARE_S1_00010002083E0832.pkg (5376 bytes) Firmware 3.00/3.01/3.10/3.15/3.20/3.21/3.30/3.40/3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65 
SYS_CON_FIRMWARE_01050101.pkg (5376 bytes) Firmware 3.41/3.42/3.50/3.55/3.56/3.60/3.61/3.65

Updater log lines related to Syscon just after BD firmware, Multi-Card controller, BlueTooth firmware (in this case CEX 3.55) just before post processing and cleanup update status :

Update System controller firmware
read SC patch package (4864 bytes) elapsed = 3 msec
read SC patch package (4864 bytes) elapsed = 3 msec
read SC patch package (4864 bytes) elapsed = 3 msec
read SC patch package (4864 bytes) elapsed = 2 msec
read SC patch package (4864 bytes) elapsed = 2 msec
read SC patch package (4864 bytes) elapsed = 3 msec
read SC patch package (4864 bytes) elapsed = 2 msec
read SC patch package (4864 bytes) elapsed = 3 msec
Update System controller firmware done(0x8002f000)